compact hd 2d exoscope vitom Search Results


90
KARL STORZ compact hd 2d exoscope vitom
(A) The operative room setting with a compact high-definition two-dimensional <t>(2D)</t> <t>exoscope</t> for a right sub-occipital/retrosigmoid craniotomy. A 2D exoscope is attached to a mechanical holding arm and held over the surgical field. Two 26 inch video monitors are positioned 2 m in front of the primary and assistant surgeons. The assistant surgeon sits on the left side of the primary surgeon. All the surgical team has the same view with the primary surgeon. (B) A 90 o 2D exoscope is held in position with a mechanical holding arm that is mounted on the operating table. (C) A 2D exoscope can be quickly switched to an endoscope. (D) A light table and high-definition camera are connected to a exoscope. (E and F) Comparison between the 2D exoscope and binocular operating microscope using in a right suboccipital/retrosigmoid craniotomy. It should be noted that the primary surgeon's head, neck, and arm are in a neutral, relaxed position when performing the surgical procedure using the 2D exoscope. The bulky head stage of the binocular operating microscope takes up the precious space of the operating field.
Compact Hd 2d Exoscope Vitom, supplied by KARL STORZ, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/compact+hd+2d+exoscope+vitom/vitom+3d+exoscope/pmc07289312-37-1-10
Average 90 stars, based on 1 article reviews
compact hd 2d exoscope vitom - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Sony 3d 4k-hd ex
Baseline characteristics of study participants and pathologies.
3d 4k Hd Ex, supplied by Sony, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/compact+hd+2d+exoscope+vitom/3d+4k+hd+ex/pmc10762452-101-23-30
Average 90 stars, based on 1 article reviews
3d 4k-hd ex - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
KARL STORZ 2d video telescopic operating microscope vitom
Baseline characteristics of study participants and pathologies.
2d Video Telescopic Operating Microscope Vitom, supplied by KARL STORZ, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/compact+hd+2d+exoscope+vitom/video+telescope+operating+monitor+vitom/10__3171_slash_2020__10__focus20786-26-231-237
Average 90 stars, based on 1 article reviews
2d video telescopic operating microscope vitom - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
KARL STORZ vitom® exoscope vitom® 2d/3d
Baseline characteristics of study participants and pathologies.
Vitom® Exoscope Vitom® 2d/3d, supplied by KARL STORZ, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/compact+hd+2d+exoscope+vitom/exoscope+vitom/pm33735886-44-8-13
Average 90 stars, based on 1 article reviews
vitom® exoscope vitom® 2d/3d - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
KARL STORZ exoscope karl-storz vitom© 3d 4k
Baseline characteristics of study participants and pathologies.
Exoscope Karl Storz Vitom© 3d 4k, supplied by KARL STORZ, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/compact+hd+2d+exoscope+vitom/3d+4k+exoscope+vitom/pm36417321-47-37-38
Average 90 stars, based on 1 article reviews
exoscope karl-storz vitom© 3d 4k - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


(A) The operative room setting with a compact high-definition two-dimensional (2D) exoscope for a right sub-occipital/retrosigmoid craniotomy. A 2D exoscope is attached to a mechanical holding arm and held over the surgical field. Two 26 inch video monitors are positioned 2 m in front of the primary and assistant surgeons. The assistant surgeon sits on the left side of the primary surgeon. All the surgical team has the same view with the primary surgeon. (B) A 90 o 2D exoscope is held in position with a mechanical holding arm that is mounted on the operating table. (C) A 2D exoscope can be quickly switched to an endoscope. (D) A light table and high-definition camera are connected to a exoscope. (E and F) Comparison between the 2D exoscope and binocular operating microscope using in a right suboccipital/retrosigmoid craniotomy. It should be noted that the primary surgeon's head, neck, and arm are in a neutral, relaxed position when performing the surgical procedure using the 2D exoscope. The bulky head stage of the binocular operating microscope takes up the precious space of the operating field.

Journal: Chinese Medical Journal

Article Title: Use of a compact high-definition two-dimensional exoscope in surgical treatment of large vestibular schwannoma

doi: 10.1097/CM9.0000000000000818

Figure Lengend Snippet: (A) The operative room setting with a compact high-definition two-dimensional (2D) exoscope for a right sub-occipital/retrosigmoid craniotomy. A 2D exoscope is attached to a mechanical holding arm and held over the surgical field. Two 26 inch video monitors are positioned 2 m in front of the primary and assistant surgeons. The assistant surgeon sits on the left side of the primary surgeon. All the surgical team has the same view with the primary surgeon. (B) A 90 o 2D exoscope is held in position with a mechanical holding arm that is mounted on the operating table. (C) A 2D exoscope can be quickly switched to an endoscope. (D) A light table and high-definition camera are connected to a exoscope. (E and F) Comparison between the 2D exoscope and binocular operating microscope using in a right suboccipital/retrosigmoid craniotomy. It should be noted that the primary surgeon's head, neck, and arm are in a neutral, relaxed position when performing the surgical procedure using the 2D exoscope. The bulky head stage of the binocular operating microscope takes up the precious space of the operating field.

Article Snippet: A compact HD 2D exoscope (ViTOM, Video Telescope Operating Microscopy; Karl Storz GmbH, Tuttlingen, Germany) was used in this study [Figure ].

Techniques: Comparison, Microscopy

Baseline characteristics of study participants and pathologies.

Journal: World Neurosurgery: X

Article Title: Comparative analysis of exoscope-assisted spine surgery versus operating microscope: A systematic review

doi: 10.1016/j.wnsx.2023.100258

Figure Lengend Snippet: Baseline characteristics of study participants and pathologies.

Article Snippet: The exoscopes used were Video Telescope Operating Monitor (ViTOM), ViTOM mounted on mechanical holding arm, ViTOM 3D model TH200, Aeos Digital Exoscope, HD-XOscope, Mitaka Kestrel View II, 3D 4K-HD EX Sony Olympus, Synaptive BrightMatter Servo, and HD-2D Stereotactic Exoscope.

Techniques: